TGR - Thermal Gradient Ring (Zimmermann's method)

TGR - Thermal Gradient Ring (Zimmermann's method)

Producent: 
Přidat žádost o nabídku
  • Popis
  • Stáhnout

TGR - Thermal Gradient Ring (Zimmermann's method)

The Thermal Gradient Ring is a novel device, which allows recording and analysis of Comprehensive Thermal Preference Phenotyping in Mice, according to Zimmermann's method. In recent years the cellular and molecular mechanisms of temperature sensing and thermoregulation are subject of intensive research. Some researchers have evidenced the limits of the existing tests: to overcome current limitations we have designed a novel circular thermal gradient assay, for thermal preference phenotyping, based on the paper "Comprehensive thermal Preference Phenotyping in Mice using a Novel Automated Circular Gradient Assay", published by University Erlangen-Nuernberg (see Zimmmermann's paper). The new TGR (Thermal Gradient Ring) provides a high degree of freedom, i.e. thermal choice, and eliminates experimenter bias. The TGR is suitable to test neuropathic pain, and allows discerning exploratory behavior from thermal selection behavior! The advantages brought about by the circular design are duplicate values, no border effects and no spatial cues, guaranteeing bias-free, reproducible data. The TGR is more sensitive than previous methods: gradient setup is superior to two plate choice design (reflects a more complex physiological environment, requires less time, less manpower and less mice). The TGR consists of a circular running track, which provides a thermal gradient between the two extremes of a cold and a hot zone (respectively 15° and 40°C in Zimmermann's paper) in which the mouse is free to move. The Thermal Insulated Ring-shaped Aluminium Runway has an ID of 45cm and 57cm OD. A heating and a heating/cooling device (both based on the well tested technology employed in Ugo Basile Hot/Cold Plate), positioned on the opposite sides of the ring, create a symmetric thermal gradient, controlled by 4 embedded thermocouples measuring the exact temperature gradient in real time. Each side of the ring is divided into 12 zones, in which the temperature Δ is proportionally divided: for example, in the protocol described in the method paper, where the two preset temperatures are respectively 15°C and 40°C, each sector represents an increment of 2.27°C. Recording and analysis of thermal preference behavior is accomplished by ANYmaze, via the USB camera which is part of the set-up. Data output include:

  • Preference Temperature time course ± SD
  • Time lag to cover zones above a defined temperature (time course)
  • Zone histogram 

The set-up includes a dedicated support, which holds a BW USB camera, and a set of 4 dual lights (visible and I.R.). The software is to be purchased separately.

Features

  • New circular design, ID 45cm, OD 57cm
  • Thermal Insulated Ring-shaped Aluminum Runway
  • Heater and cooler on opposite sides, to establish a symmetric gradient
  • 12 zones per side (specular), 40cm2 each
  • 4 thermocouples embedded in the thermal gradient ring
  • CCD-camera (included in the standard package, with its dedicated support) and ANYmaze video-tracking software
  • The system includes a set of 4 dual (visible/I.R.) lights ideal for videotracking: perfect view even in the dark

Benefits

  • Duplicate values, no border effects, no spatial cues
  • More sensitive than previous methods: bias-free, reproducible data
  • Gradient setup superior to two-plate choice design
  • Temperature Δ proportionally divided into 12 (in the method paper 15°C-40°C = 2.27°C per zone)
  • The exact temperature gradient measured in real time
  • Behavior recorded automatically during 60 minutes

General

  • Operating Temperature: HEATING DEVICE : from room temperature to 65°C, HEATING/COOLING DEVICE: from 4° to 35°C
  • Controls: Commands on the heater/cooler front panel
  • Preset Temperature Read-out: On LED display on the heating/cooling devices' front panel
  • Detection: Via ANYmaze software
  • Temperature feedback: Measured by 4 thermocouples and monitored by ANYmaze software in real time
  • Sound: Negligible
  • Power: Universal input 85-264 VAC, 50-60Hz

Physical

  • Aluminum Runway: ID 45cm, OD 57cm
  • Circular Enclosures: 24cm high
  • Dimensions: 87x64x64(h)cm
  • Weight: 39Kg
  • Shipping Weight: 57Kg
  • Packing Dimensions: 100x80x70(h)cm (wooden pallet)

Warranty

35550 is covered by a 24-month warranty

Application

"Currently available behavioral assays to quantify normal cold sensitivity, cold hypersensitivity and cold hyperalgesia in mice have betimes created conflicting results in the literature. Some only capture a limited spectrum of thermal experiences, others are prone to experimenter bias or are not sensitive enough to detect the contribution of ion channels to cold sensing because in mice smaller alterations in cold nociception do not manifest as frank behavioral changes. To overcome current limitations we have designed a novel device that is automated, provides a high degree of freedom, i.e. thermal choice, and eliminates experimenter bias. The device represents a thermal gradient assay designed as a circular running track. It allows discerning exploratory behavior from thermal selection behavior and provides increased accuracy by providing measured values in duplicate and by removing edge artifacts. Our custom-designed automated offline analysis by a blob detection algorithm is devoid of movement artifacts, removes light reflection artifacts and provides an internal quality control parameter which we validated. The assay delivers discrete information on a large range of parameters extracted from the occupancy of thermally defined zones such as preference temperature and skew of the distribution. We demonstrate that the assay allows increasingly accurate phenotyping of thermal sensitivity in transgenic mice by disclosing yet unrecognized details on the phenotypes of TRPM8-, TRPA1- and TRPM8/A1-deficient mice."

"Comprehensive thermal preference phenotyping in mice using a novel automated circular gradient assay"

Components & Accessories

35550

Thermal Gradient Ring, complete assembly, including heating device, heating/cooling device, circular runway with circular enclosures, B/W USB Camera 35550-035 with dedicated support and set of dual (visible/I.R.) lights

VIDEOTRACKING

60000

ANY-maze Software

banner_allentown_cz.jpg