Mouse Intermittent IV Dose
Short-term, low-stress dosing through a catheter without a tether.
This system is designed for doses of up to several minutes at a time, whether from a syringe pump or a manual bolus. In these cases direct injections could cause too much stress or trauma over the course of a study, but a continuous tethered system is overkill for the short duration of the dose.
Catheterized animals with Vascular Access Buttons™ can be group housed using the protective cap. To dose, move the animal into a temporary cage and connect the pump or syringe using PinPort™ extension set to the VAB™ port. If the animal is monitored and not overly active during the dose, a swivel and protective spring tether should not be needed. Flush in the balance of the dose with an appropriate sterile flush or lock solution and return the animal to group housing until the next dose.
See below for a typical application setup with a list of components. If you need any assistance in selecting other setup parts, please don't hesitate to contact the Animalab team.
- HA1100 Pump 11 Elite infuse-only single syringe pump (704500)
- PNP3MC/25-12 PinPort extension set: PinPort connector, 12in (30cm) PU tubing, 25ga luer stub, sterile
- VABM1B/25 Vascular Access Button for mouse, magnetic, 1 channel 25ga, injector
- C20PU-MJV2013 Mouse JVC, PU 2Fr 10cm, 13mm insertion length (a1.2cm), round tip. LS25 and SP25/12. Fits 25ga.
- VABM1C-5 Protective aluminum caps for magnetic 1 channel mouse VAB, package of 5 different colors
- VABMG Handling tool for magnetic mouse Vascular Access Buttons, purple
- PNP3M PinPort injectors, 50 sterile pouches of 5 (250 pcs)
- USP-HS-020-1-NJ1P-50 Sterile catheter flush solution, heparin (20 USP units/mL) in 0.9% saline, 50 pcs (10 packs of 5) 1mL in 1mL syringe, PinPort injector
- USP-S-1-BD1P-50 Sterile catheter flush solution, 0.9% saline, 50 pcs (10 packs of 5) 1mL in 1mL syringe, PinPort injector