ChemoMetec

NucleoCounter® NC-202™

Code NC-202

Consistent Cell Counter

  • Consistent results across instruments, users and sites
  • Use with Via2-Cassette™ to eliminate human error
  • Monitor production runs with DebrisIndex™
  • Increased cell counting range: No more dilutions
  • Scalable system with 21 CFR Part 11/GMP-ready software
Read more about product
Features

Description

The NucleoCounter® NC-202™ automated cell counter is the most precise on the market. It is used in a wide range of industry and research applications and is our 3rd generation automated cell counter with improved functionality.

Our cassette-based instrument features upgraded hardware and new NC-View™ software. The combined inter-operator and inter-instrument variation is extremely low. This means you get identical results with any cell sample, recorded by any user, anywhere in the world.

The DebrisIndex™ feature measures culture debris build-up. Debris negatively affects downstream filtering and purifications steps, so directly measuring debris facilitates better process development parameters. Learn more about DebrisIndex™.

The NC-View™ software is compatible with 21 CFR Part 11/GMP guidelines and can be integrated into your clinical workflow.

The disposable Via2-Cassette™ combined with the NucleoCounter® NC-202™ automated cell counter create a closed cell counting system, helping you stay protected when handling samples. No pipettes, no exposure to (toxic) reagents, and minimal clean-up make the NucleoCounter® system a safe option.

Read more about the Cassette technology

Any sample. Any user. Anywhere.

Specifications
  • Application type(s): Cell count & viability analysis 
  • Cell type(s): Mammalian cells incl. cell lines & primary cells, whole blood samples, leukopaks, PBMCs, MSCs, T cells; yeast and insect cells, CEFs; cells on microcarriers, in aggregate or 3D cultures 
  • Software: NC-View™ 
  • Consumable(s): Via2-Cassette™ 
  • Capacity (Analysis time): 30 seconds 
  • Analysis volume: 1.35 μl (volume-calibrated Via2-Cassette™) 
  • Optimal range: 5×104 to 1×107 cells/ml 
  • Staining dye(s): Acridine orange (AO) and DAPI 
  • Loading volume: 60 μl 
  • Excitation: 2 LED light sources with peak wavelengths at 365 nm and 505 nm 
  • Emission: A single dual-band emission filter: 410 – 460 nm and 540 – 650 nm 
  • Optics: Lens with ×2.1 magnification, 2/3” CMOS camera 
  • Data output: Images, tables 
  • Data export formats: .cm, .csv, .pdf 
  • Product number: 900-2020 
  • Size: 40 × 23 × 25 cm (W × H × D) 
  • Weight: 4.9 kg (10.8 lb) 
  • Supply Voltage: 24VDC (100-240V ~ 50-60Hz)